motor workbench 设置问题,工程文件不生成
控制板:nucleo-f303re驱动板:X-NUCLEO-IHM07M1电机:longwaymotor
现在的问题是,用Motor Profiler 5.2.0 测试电机参数,已连接成功,并测出电机的相应参数。但用workbench新建工程后,不能自动生成工程文件。报错如下。不明白需要改哪里?
TypeTime Motor Id Message
UNK 08:54:481 Phase 2 - Final speed final speed is higher then max motor rated speed
UNK 08:54:481 Phase 3 - Final speed final speed is higher then max motor rated speed
UNK 08:54:481 Phase 4 - Final speed final speed is higher then max motor rated speed
UNK 08:54:481 Phase 5 - Final speed final speed is higher then max motor rated speed
UNK 08:54:481 Speed is higher then max motor rated speed
UNK 08:54:481 motor nominal current value is higher than over current protection
本帖最后由 toofree 于 2018-9-20 15:59 编辑
提示的比较清楚了呀,找到Phase 2到5相关设置,把速度调低。
页: