永夜衣袂 发表于 2018-5-25 10:00:33

QSPI连续快速读取速度很慢,时钟不太对

参考论坛一个帖子的配置方法,如下Init QSPI,以及读取时先发送 QSPI_QUAD_INOUT_FAST_READ_4_BYTE_ADDR_CMD,在接手500个字节的数据,可是时钟信号出来如图并不是连续的,然后读取速度就很慢。

QSPI_StaticTypeDef QSPI_UserInit(void)
{
uint32_t i;
uint8_tQspiID;
__IO QSPI_StaticTypeDef__QspiStatus = QSPI_OUT_TIME;
       
        if(g_isQSPIInit)
        {
                return QSPI_OK;
        }
g_isQSPIInit = 1;
       
QUADSPI_Init();   

__QspiStatus = QSPI_ResetMemory(&hqspi);

        if ( __QspiStatus != QSPI_OK)
        {
    printf("QSPIreset memory Error... ... \r\n");   
                return QSPI_ERROR;
        }

i = 0x100000;
while(i --)
{

}
       
                QSPI_Read_ID(QSPI_READ_ID_CMD, (uint8_t *) & QspiID, 3);
                QSPI_AutoPollingMemReady(&hqspi);
        QSPI_DummyCyclesCfg(&hqspi);
_QspiFlashInf.Id = (QspiID << 16) | (QspiID << 8) | QspiID;
#ifdef DEBUG
   printf("QSPI_READ_ID =0x%X\r\n", _QspiFlashInf.Id );
#endif
__QspiStatus = QSPI_Quad_Enter();

#ifdef DEBUG
printf("QSPI_UserInit                  OK       ... DD \r\n\r\n");
#endif
return QSPI_OK;
}
void QUADSPI_Init(void)
{

hqspi.Instance = QUADSPI;

HAL_QSPI_DeInit(&hqspi);

hqspi.Init.FifoThreshold = 10;                     
hqspi.Init.SampleShifting = QSPI_SAMPLE_SHIFTING_HALFCYCLE;
hqspi.Init.FlashSize = QSPI_FLASH_SIZE_LINE;


hqspi.Init.ClockPrescaler = 1;
hqspi.Init.ChipSelectHighTime = QSPI_CS_HIGH_TIME_4_CYCLE;



hqspi.Init.ClockMode = QSPI_CLOCK_MODE_3;               
hqspi.Init.FlashID = QSPI_FLASH_ID_1;                  
hqspi.Init.DualFlash = QSPI_DUALFLASH_DISABLE;   
if (HAL_QSPI_Init(&hqspi) != HAL_OK)
{

}
}


/*
int QSPI_Read(uint8_t* data, uint32_t address, uint32_t size)        --Read data from QSPI flash
A function to read data from QSPI flash
Return an integer value (default QSPI_OK), a parameter for data buffer,
a parameter for QSPI memory address, a parameter for data size.
*/

QSPI_StaticTypeDef QSPI_ReadBuff(uint8_t* data, uint32_t address, uint32_t size)
{
uint32_t__InstructionMode, __AddressMode, __DataMode;
uint8_t readBuffer_RegVal = 0;

if(QSPI_WorkMode)   // Work In QUAD Model
{
    __InstructionMode = QSPI_INSTRUCTION_4_LINES;
    __AddressMode   = QSPI_ADDRESS_4_LINES;
    __DataMode      = QSPI_DATA_4_LINES;
}
else
{
    __InstructionMode = QSPI_INSTRUCTION_1_LINE;
    __AddressMode   = QSPI_ADDRESS_1_LINE;
    __DataMode      = QSPI_DATA_1_LINE;
}

if(QSPI_SendCmdData(QSPI_QUAD_INOUT_FAST_READ_4_BYTE_ADDR_CMD,
                        __InstructionMode,            
                        __AddressMode,                  
                        QSPI_ADDRESS_32_BITS,         
                        __DataMode,                  
                        size,                        
                        4 ,                           
                        address,                        
                        &readBuffer_RegVal,                  
                        QSPI_SEND_CMD                  
                     ) != QSPI_OK )
{
    return QSPI_ERROR;
}   

if(QSPI_Receive(data,size) != QSPI_OK)
    returnQSPI_ERROR;
       
returnQSPI_OK;

}

永夜衣袂 发表于 2018-5-25 15:39:10

自顶,求助,各位大佬有没有用过QSPI的探讨下,用正点原子的源码,时钟波形也是这么断续的,看不出来QSPI连续读取的样子

feixiang20 发表于 2018-5-26 00:40:02

要么你修改读取代码里的参数,看看有什么变化

butterflyspring 发表于 2018-5-30 11:01:33

你用CUBEMX生成一个例程看看,或者看看我们的例程代码,对比一下.你这个只能自己调试进去看看,实在不行,DMA模式,QSPI高速时,轮训模式是跟不上的
页: [1]